Novelty Occitanie agency website

ISEMCON - SC-1

Acoustic calibrator with sinusoidal frequency generator referenced at 1 kHz whose level can be chosen between two standard values 94 and 110 dBSPL

Documents to download

Product details

Description
The SC-1 acoustic calibrator consists of a 1 kHz referenced sinusoidal frequency generator whose level can be chosen between two standard values 94 and 110 dBSPL, a transducer and a microphone capsule coupler/adapter. The coupler allows you to receive a wide choice of microphone capsules. It can be used to check the accuracy and sensitivity of measurement microphones. The SC-1 requires a standard 9V battery to operate. IEC 60942 class: 2.

Note: The SC-1 calibrator must be equipped with a coupling adapter (optional) to be chosen according to the type of capsule(s) to be calibrated.
Optional 1/2″, 1/4″ and 8 mm adapters are available (other versions on request).

  • Automatic compensation of thermal and hydrometric changes (modifications).
  • Powered by standardised 9V battery.
  • Detecting the battery status.
  • Designed, manufactured and calibrated in Europe.
  • Class: 2.
  • 2-year warranty.
  • Coupler system, adapter.
  • Various couplers as standard 1/4″, 1/2″, 8 mm or on request.

A calibrator allows you to calibrate your measuring device. The Smaart V7 software , like other measurement tools, is equipped with a sound level meter. It is essential to calibrate your measurement chain, which allows you to have a real and not relative reading of the measured sound pressure levels.

A calibrator usually comes in the form of a tube, it can receive different adapters or tips, depending on the size of the capsule to be calibrated (1/4″, 1/2″, 8 mm, 10 mm… etc.). It is equipped with a cavity where the capsule to be tested is inserted. A calibrator is capable of generating a frequency of 1,000 Hz at 94 dBSPL, some have different level selections (94, 110,  114 dBSPL).??

In its use, this calibrator will allow you to calibrate your measurement platform and establish a defined relationship between the relative electrical levels provided by your sound card (levels from your microphone preamplifier) and a sound pressure level expressed in dBSPL.

?? Sound Level 😕 Summary
The sensitivity of a measurement microphone (capsule) is expressed in mV/Pa (@ 1KHz) or dBV/Pa (@ 1KHz). The capsule, when it picks up a change in pressure, transcribes it into the output by a change in the voltage. The measurement microphone is connected to a sound card with a preamplifier, the sensitivity or gain setting of the preamplifier depends on the sensitivity of the source capsule, but when reading from your measurement platform, the level or amplitude will be expressed in dBFS.

Scale translation: mV/Pa to dBSP
L?Having a standard source calibrated at 94 dBSPL (calibrator) using the reference frequency of 1,000 Hz will allow the measurement platform to be calibrated to have a unit reading in the acoustic world: dBSPL  and above all to have a real calibrated sonometry tool.

?? Materials needed 😕

  • 1 computer (Mac or PC) with Smaart V7 (or any other measurement software supporting this feature).
  • 1 Acoustic calibrator that can generate 1 KHz @ 94 dBSPL. (with the corresponding adapter or end cap).
  • 1 Measurement microphone.
  • 1 sound card (with mic preamp and phantom power).

Spec:

  • Frequency 1kHz +- 0.2%
  • SPL 110dB – 94dB switchable
  • Accuracy +- 0.5dB at 20 Grad Celsius and 1013 mbar
  • ambient temperature range 0 – 45 Grad Celsius
  • Temperature drift < 0.02dB per Grad Celsius
  • Temperature drift frequency: < 0.05Hz per Grad Celsius
  • Storage temperature range -25 – 55 Grad Celsius (without battery)
  • humidity 5 to 95% relative
  • Power supply 9V battery or accumulator
  • Housing Aluminium, PVC
Contact us